Welcome to your 2365 625 Electrical design
1.
Under the EAWR 1989 before work may commence it must be shown that a person is what?
2.
The correct title for the conductors that carry the electrical supply in between levels of a building is known as a?
3.
If class II and class I cabling is in the same cable space, how should it be placed?
4.
The type of trunking that can be used as a circuit protective conductor is?
5.
Which one of the following devices is suitable for an installation supplying an X-ray machine in a hospital?
6.
The IET Wiring Regulations Appendices has information relating to cable selection on which of the following?
7.
Spring toggles are used to fix electrical equipment to?
8.
What cable is used to connect lots of computers in a LAN that is suitable for high rates of data transmission?
9.
The minimum bending radii of Mineral Insulated (MICC) cable is how many times the cable diameter for: rework (and non-rework)
10.
The Health and Safety at Work Act...
11.
A circuit installed to supply a fire panel would be identified as?
12.
Which of these is not covered by the scope of BS7671?
13.
If a ring final circuit has a 32A fuse and a 230 V supply, the maximum power available at any one time should be no more than?
14.
If the voltage drop in an installation exceeds the permissible value it may be corrected by?
15.
It is the duty of all employees to?
16.
If conductors are not clean when making a joint with a crimping tool the most likely results will be?
17.
Which of the following is a cartridge fuse?
18.
The term for a requirement in a Regulation as "absolute" means it?
19.
The correct tool used to cut a 16mm² copper cable to length is?
20.
What is meant by the term zonal concept?
21.
Which of the following is a re-wireable fuse?
22.
A type of emergency light fixture that only illuminates when the power fails is called?
23.
Mineral insulated metal sheathed cable has insulation which is?
24.
If conductors are not clean when making a joint with a crimping tool the most likely results will be?
25.
Which one of the following is a short circuit protection device that is NOT activated by heat?
26.
Which one of the following devices would be BEST suited to fixing 20mm² pvc conduit saddles to a concrete wall?
27.
Cables in wooden joists must be at least what distance from the top or bottom?
28.
Which of the following is a miniture circuit breaker?
29.
Which one of the following is the conduit capacity factor to be used where a 25mm² conduit has 2 bend in a 6m run?
30.
At what depth should a Steel Wired Armoured (SWA) cable be buried on an agricultural premises?